info@buecher-doppler.ch
056 222 53 47
Warenkorb
Ihr Warenkorb ist leer.
Gesamt
0,00 CHF
  • Start
  • Investigations of After Cavity Interaction in Gyrotrons Including the Effect of Non-uniform Magnetic Field

Investigations of After Cavity Interaction in Gyrotrons Including the Effect of Non-uniform Magnetic Field

Angebote / Angebote:

Dynamic after-cavity interaction (ACI) in megawatt-class gyrotrons is investigated that could lead to lower output mode purity and increased level of internal stray radiation. The self-consistent KIT-IHM multi-mode-code SELFT has been modified to extend the simulation domain into the radius up-taper section of the gyrotron cavity where the probability of ACI exists. Studies on four different gyrotron configurations confirm that undesired interactions in the up-taper region can result in additional parasitic oscillations with relative power in the 1%-range.This work was published by Saint Philip Street Press pursuant to a Creative Commons license permitting commercial use. All rights not granted by the work's license are retained by the author or authors.
Fremdlagertitel. Lieferzeit unbestimmt

Preis

99,00 CHF

Artikel, die Sie kürzlich angesehen haben